NETA FIELD SERVICES & ASSET RELIABILITY
Tested for the Way Your System Has to Perform
Electrical assets can appear operational while hidden deterioration, incorrect settings, installation defects, or developing faults increase risk. POWERX provides NETA field services and advanced diagnostics to verify new systems, understand existing asset condition, support maintenance decisions, and respond when performance changes unexpectedly.
POWERX supports low-, medium-, and high-voltage equipment, protection and control systems, cables, grounding, generators, and critical facility infrastructure. When testing reveals a broader need, the work can connect to engineering, discipline-specific commissioning, Genelco-led integrated commissioning, or modernization.
NETA Field Services & Asset Reliability
Need a concise overview to review or share? Enter your information and we will email the service sheet directly to you.
Where This Expertise Supports the Lifecycle
Select any stage to see what else POWERX does there.
ASSET RELIABILITY
Reliability Is Built Over the Life of the System
Energization is not the finish line. Equipment ages, operating conditions change, maintenance cycles return, and new demands reshape the system. POWERX helps customers understand asset condition, address developing risk, and make informed decisions throughout the life of their power infrastructure.
Plan & Assess
Establish the technical baseline through system studies, existing-condition reviews, asset data, maintenance planning, and reliability strategy.
Related Capabilities
- Power System Studies
- Installed-Base Evaluations
- Technical Audits
- Asset and Reliability Planning
- One-Line and System-Data Verification
Core Capabilities
Acceptance Testing
Visual, mechanical, electrical, functional, and system-level testing to verify installation, condition, performance, and readiness before energization or turnover.
Read More ›Maintenance Testing
Routine and condition-based testing, trending, inspection, and recommendations that support reliability, asset life, outage planning, and compliance.
Read More ›Equipment Testing & Diagnostics
Transformers, breakers, switchgear, relays, cables, rotating equipment, grounding, batteries, UPS, transfer switches, motors, generators, and related assets.
Read More ›Advanced Diagnostics
Infrared thermography, partial discharge, VLF, tan delta, DGA, power quality, load monitoring, SF6 analysis, ground testing, and fault location.
Read More ›Cable & Generation Services
High- and medium-voltage cable termination, splicing, testing, fault location and repair; generator control and excitation testing, troubleshooting, and upgrades.
Read More ›Emergency, OEM & Modernization Support
Troubleshooting, emergency diagnostics, OEM representation, third-party inspection, retrofit, equipment replacement, relay configuration, and post-construction support.
Read More ›Why Customers Choose POWERX
- NETA Accredited Company capability across POWERX and InRush scopes
- Calibrated testing equipment and standards-based procedures
- Actionable reporting connected to engineering and field solutions
- Expanded cable, generator, and Canadian coverage through InRush
When to Bring Us In
- New equipment needs acceptance testing before energization.
- Operating assets require scheduled maintenance, diagnostics, or condition trending.
- A facility is experiencing nuisance trips, heat, power-quality issues, abnormal readings, or equipment concerns.
- A planned outage must be used efficiently across multiple assets and technical disciplines.
- An unplanned event requires safe triage, troubleshooting, repair coordination, or root-cause support.
- Aging infrastructure needs retrofit, replacement, modernization, or a longer-term reliability program.
What the Work Can Deliver
Scope-specific deliverables may include test plans, equipment records, calibrated test data, pass/fail criteria, condition assessments, trend information, thermal images, diagnostic interpretation, deficiency lists, repair or replacement recommendations, as-left settings, cable records, maintenance plans, and reports formatted for the customer, project team, utility, AHJ, insurer, or audit process as applicable.
Systems and Applications
Transformers, switchgear, switchboards, breakers, relays, cables and busways, grounding systems, motors, generators, rotating equipment, UPS, batteries, transfer switches, capacitors, reactors, arresters, MCCs, controls, instrument transformers, and low-, medium-, and high-voltage systems within the approved team competency and equipment range.
Explore This Expertise
Acceptance Testing
New Equipment Should Not Require Blind Trust
Open Page ›Maintenance Testing
Reliability Is Built Before the Outage
Open Page ›Equipment Testing & Diagnostics
Understand What Your Equipment Is Telling You
Open Page ›Infrared Thermography
See the Heat Before It Becomes Failure
Open Page ›Power Quality & Optimization
Find the Condition Behind the Symptom
Open Page ›Emergency Response
When the System Changes, Clarity Matters
Open Page ›Cable Termination, Splicing & Fault Location
Protect the Connection Between Critical Assets
Open Page ›Generator Controls & Excitation
Connect Machine Response, Protection, and Control
Open Page ›OEM Support & Troubleshooting
The Manufacturer Built It, We Help Prove It Works on Your Site
Open Page ›Retrofit & Modernization
Upgrade the System Without Losing Control of the Transition
Open Page ›FAQs
Acceptance testing establishes that newly installed or modified equipment is ready for service. Maintenance testing evaluates equipment already in operation, supports condition trending, and helps prioritize corrective action and future outages.
No. Some services, such as thermography and selected monitoring, are performed under operating load. Other tests require de-energization, grounding, isolation, or an outage. The safe work method is determined by the equipment, test, standard, and site conditions.
The exact package depends on scope, but it clearly identifies equipment, procedures, test data, criteria, findings, deficiencies, and recommended next steps.
Yes. Through InRush, POWERX provides HV and MV cable termination, splicing, VLF, tan delta, partial-discharge testing, fault location, generator controls, and excitation expertise. InRush certifications include Pfisterer systems up to 240 kV and 3M, Elastimold, and Raychem systems up to 35 kV.
Engineering services are performed by licensed professional engineers in jurisdictions where required.